Detailed Product Description
Name: Wellhead Joint Wireline Pressure Control Equipment Size: 2inch ID - 5inch ID
Service: Standard&H2S Material: Alloy Steel&Nickel Alloy
Connection Type: O&B Function: Allows For Only The Joint That Was Broken To Be Tested, Without Filling The Whole Lubricator System
Work Pressure: 3k 5k 10k 15k
High Light:

Wellhead Joint Wireline Equipment

,

Alloy Steel Wireline Equipment

,

2 Inch ID Wireline Equipment

 Wellhead Joint Wireline Pressure Control Equipment Alloy Steel

 

Wireline Wellhead Joint Wireline Pressure Control Equipment

I. Overview:

 The wellhead joint is used to connect the blowout preventer with the wellhead, with the upper part connected with the blowout preventer and the lower part connected with the wellhead. The wellhead joint is sealed by threads. When in use, the wellhead connector can be directly tightened on the thread of the wellhead after winding the thread with tetrafluoroethylene tape or applying anti-sticking grease on the thread.

II.the pressure test:

Wellhead joints shall be tested for compressive strength at regular intervals, and the test pressure shall be 1.5 times of the working pressure.

1. Install the pressure test joint and connect the pressure test pipeline;

2. Start the pressure test pump for pressure test: press it to the test pressure, hold it for 15 minutes without leakage, and fill in the test record card.

III. Routine maintenance:

1. The pressure test shall be conducted regularly;

2. When temporarily not in use, it should be stored with silk protector.

Welcome to contact us at any time.

Wellhead Joint Wireline Pressure Control Equipment Alloy Steel 0

Contact Details
Ruixin Energy Equipmnet

Contact Person: Selina Qiang

Tel: 86 13571793445

Send your inquiry directly to us
Ruixin Energy Equipmnet
Room 1901, Block A, Saigao District Building, Feng Cheng Five Road, Xi 'an Economic and Technological Development Zone, Shaanxi Province
Tel:00-86-13571793445
Mobile Site Privacy Policy | China Good Quality Wireline Tool String Supplier. © 2021 - 2024 rxwirelinetools.com. All Rights Reserved.